PowerAir Fuse Test and Repair

The fuse protects the low voltage control system against overload failure, mainly short circuits. It is located in the electrical box and accessed on top of the electrical box.

PowerAir Fuse

Fuse Check

1.Turn power off.

2.Remove electrical box cover. Refer to: Electrical box cover

PowerAir Fuse Check

3.Remove terminal leads. Test continuity. Set meter to Ω. Place meter probes on both fuse terminals.

Refer to table below.

PowerAir  Fuse Check

4.Remove fuse from electrical box. Push in and turn cap counter clockwise.

5.Visually check to see if fuse is burnt or broken. If fuse is burnt or broken, replace with a 1/3 amp 250V Slo-Blo fuse.

6.Reinstall into electrical box. Push in and turn cap clockwise until it locks in place.

Meter Required

Status

Required Action

OL offline.

Thumbs Down

Replace Fuse. 1/3 amp 250V Slo-Blo fuse

Continuity checks ok. Visually looks ok.

Thumbs Up

Fuse is Good.