Midmark® Dental Halogen Light Wiring Diagram
Model |
153673 |
Serial Number | All NW, RE, PV Prefixes and V2200 thru V1467258 |
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
117244 | Connector |
C |
015-2569-01 | Ground Wire |
D |
015-1465-00 | Lamp Socket Harness |
E |
015-2580-00 | Switch Panel Harness |
F |
015-1522-00 |
Harness 96" (244 cm) |
G |
015-1592-00 | Knight Console Harness |
H |
152969 | Console Light Umbilical Harness |
Power Suppy Options | ||
I | 152964-01 | 115 VAC |
J | 152971-01 | 230 VAC |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153937-002 | ||
Serial Number | V1467259 thru Present |
VAC at Board | |
---|---|
High | 14.5 - 19.5 VAC |
Medium | 13 - 18 VAC |
Low | 10.5 - 16 VAC |
Composite | 6 - 14 VAC |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
117244 | Connector |
C |
015-2569-01 | Ground Wire |
D |
015-1465-00 | Lamp Socket Harness |
E |
015-2580-00 | Switch Panel Harness |
F |
015-3247-00 | Knight Flex Arm Light Harness |
G |
015-3280-00 | Knight Fixed Arm Light Harness |
H |
015-3246-00 | Knight Light Harness to J-Box - Length 94" (239 cm) |
I |
015-2336-05 | Three Wire Connector |
J |
Power Cord Assembly Options | |
123108-01 | 115 VAC | |
015-1510-01 | 230 VAC | |
Power Supply Options | ||
K | 153935-001 | 115 VAC |
L | 153935-002 | 230 VAC |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153584 |
Serial Number | All NW, RE, PV Prefixes and V2200 thru V1467258 |
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
117244 | Connector |
C |
015-2569-01 | Ground Wire |
D |
015-1465-00 | Lamp Socket Harness |
E |
015-2580-00 | Switch Panel Harness |
F |
015-1522-00 |
Harness 96" (244 cm) |
G |
015-1484-00 | LR Only - Jumper Harness 40" (102 cm) |
H |
J-Box to Unit Light Harness Options | |
015-1586-00 | Length 94" (239 cm) | |
015-1586-01 | Length 130" (330 cm) | |
Power Supply Options | ||
I | 152964-01 | 115 VAC |
J | 152971-01 | 230 VAC |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153937-004 |
Serial Number | V1467259 thru Present |
VAC at Board | |
---|---|
High | 14.5 - 19.5 VAC |
Medium | 13 - 18 VAC |
Low | 10.5 - 16 VAC |
Composite | 6 - 14 VAC |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
117244 | Connector |
C |
015-2569-01 | Ground Wire |
D |
015-1465-00 | Lamp Socket Harness |
E |
015-2580-00 | Switch Panel Harness |
F |
015-3247-00 | Harness 96" (244 cm) |
G |
015-3280-00 | Jumper Harness 40" (102 cm) |
H |
Knight Light Harness to J-Box Options | |
015-3246-00 | Length 94" (239 cm) | |
015-3246-01 | Length 130" (330 cm) | |
I |
015-2336-05 | Three Wire Connector |
J |
Power Cord Assembly Options | |
123108-01 | 115 VAC | |
015-1510-01 | 230 VAC | |
Power Supply Options | ||
K | 153935-001 | 115 VAC |
L | 153935-002 | 230 VAC |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153585 | 153771 |
Serial Number | All NW, RE, PV Prefixes and V2200 thru V1315736 | All NW, RE, PV Prefixes and V2200 thru V1315736 |
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
117244 | Connector |
C |
015-2569-01 | Ground Wire |
D |
015-1465-00 | Lamp Socket Harness |
E |
015-1324-04 | Connector |
F |
015-2580-00 | Switch Panel Harness |
G |
015-1522-00 |
Harness 96" (244 cm) |
H |
015-1484-00 | LR Only - Jumper Harness 40" (102 cm) |
I |
015-1468-00 | J-Box to Unit Light Harness |
Power Supply Options | ||
J | 153606 | 115 VAC |
K | 153642 | 230 VAC |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153914 | 153818 | |
Serial Number | V1315737 thru V1765598 | V1315737 thru V1765598 |
VAC at Board | |
---|---|
High | 14.5 - 19.5 VAC |
Medium | 13 - 18 VAC |
Low | 10.5 - 16 VAC |
Composite | 6 - 14 VAC |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
015-2569-01 | Ground Wire |
C |
117244 | Connector |
D |
015-1465-00 | Lamp Socket to PCB Harness |
E |
015-1324-04 | Connector |
F |
015-2580-00 | Switch Panel Harness |
G |
015-2346-00 | Light Power/LIN Harness |
H |
015-2344-00 | Use for LR Mtd. Lights Only - Light Power/LIN Harness Jumper |
I |
Light Power/LIN Harness Options | |
015-2329-00 | LR Mounted 9.5 ft. (2.9 m) | |
015-2329-01 | Console Mounted 12 ft. (3.7 m) | |
015-2329-02 | LR Mounted 13.5 ft. (4.1 m) | |
015-2329-03 | Console Mounted 16 ft. (4.9 m) | |
Power Supply Options | ||
J | 153808-001 | 115 VAC |
K | 153808-002 | 230 VAC |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153914 | 153818 | |
Serial Number | V1765599 thru Present | V1765599 thru Present |
VAC at Board | |
---|---|
High | 14.5 - 19.5 VAC |
Medium | 13 - 18 VAC |
Low | 10.5 - 16 VAC |
Composite | 6 - 14 VAC |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
015-2569-01 | Ground Wire |
C |
117244 | Connector |
D |
015-1465-00 | Lamp Socket to PCB Harness |
E |
015-1324-04 | Connector |
F |
015-2580-00 | Switch Panel Harness |
G |
015-2346-00 | Light Power/LIN Harness |
H |
015-2344-00 | Use for LR Mtd. Lights Only - Light Power/LIN Harness Jumper |
I |
Light Power/LIN Harness Options | |
015-2329-00 | LR Mounted 9.5 ft. (2.9 m) | |
015-2329-01 | Console Mounted 12 ft. (3.7 m) | |
015-2329-02 | LR Mounted 13.5 ft. (4.1 m) | |
015-2329-03 | Console Mounted 16 ft. (4.9 m) | |
Power Supply Options | ||
J | 153941-003 | 115 VAC |
K | 153941-004 | 230 VAC |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153818 | |
Serial Number | V2200 Thru V1765598 |
VAC at Board | |
---|---|
High | 14.5 - 19.5 VAC |
Medium | 13 - 18 VAC |
Low | 10.5 - 16 VAC |
Composite | 6 - 14 VAC |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
015-2569-01 | Ground Wire |
C |
117244 | Connector |
D |
015-1465-00 | Lamp Socket to PCB Harness |
E |
015-1324-04 | Connector |
F |
015-2580-00 | Switch Panel Harness |
G |
015-2346-00 | Light Power/LIN Harness |
H |
015-2344-00 | Use for LR Mtd. Lights Only - Light Power/LIN Harness Jumper |
I |
Light Power/LIN Harness Options | |
015-2329-00 | LR Mounted 9.5 ft. (2.9 m) | |
015-2329-01 | Console Mounted 12 ft. (3.7 m) | |
015-2329-02 | LR Mounted 13.5 ft. (4.1 m) | |
015-2329-03 | Console Mounted 16 ft. (4.9 m) | |
J |
Chair to Power Supply LIN Harness Options | |
015-2149-01 | Length: 72" (183 cm) | |
015-2149-03 | Length: 120" (305 cm) | |
Power Supply Options | ||
K | 153808-001 | 115 VAC |
L | 153808-002 | 230 VAC |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153818 | |
Serial Number | V1765599 Thru Present |
VAC at Board | |
---|---|
High | 14.5 - 19.5 VAC |
Medium | 13 - 18 VAC |
Low | 10.5 - 16 VAC |
Composite | 6 - 14 VAC |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
015-2569-01 | Ground Wire |
C |
117244 | Connector |
D |
015-1465-00 | Lamp Socket to PCB Harness |
E |
015-1324-04 | Connector |
F |
015-2580-00 | Switch Panel Harness |
G |
015-2346-00 | Light Power/LIN Harness |
H |
015-2344-00 | Use for LR Mtd. Lights Only - Light Power/LIN Harness Jumper |
I |
Light Power/LIN Harness Options | |
015-2329-00 | LR Mounted 9.5 ft. (2.9 m) | |
015-2329-01 | Console Mounted 12 ft. (3.7 m) | |
015-2329-02 | LR Mounted 13.5 ft. (4.1 m) | |
015-2329-03 | Console Mounted 16 ft. (4.9 m) | |
J |
Chair to Power Supply LIN Harness Options | |
015-2149-01 | Length: 72" (183 cm) | |
015-2149-03 | Length: 120" (305 cm) | |
Power Supply Options | ||
K | 153941-001 | 115 VAC |
L | 153941-002 | 230 VAC |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153637 | |
Serial Number | All NW, RE, PV Prefixes and V2200 thru V1467258 |
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
117244 | Connector |
C |
015-2580-01 | Switch Panel Harness |
D |
015-1465-01 | Lamp Socket Harness |
E |
015-2569-02 | Ground Wire |
F |
015-1324-04 | Connector |
G |
015-1513-00 | Flex / Fixed Arm Harness |
H |
015-1514-00 | Transformer / Suspension Tube Harness |
I |
015-0737-09 | Jumper Wire |
J |
015-0737-05 | Jumper Wire |
K |
015-0737-06 | Jumper Wire |
L |
015-0737-11 | Jumper Wire |
M |
015-1516-00 | Suspension Tube Harness - Use with 26.25" tube and longer |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153637 | |
Serial Number | V1467259 to Present |
VAC at Board | |
---|---|
High | 14.5 - 19.5 VAC |
Medium | 13 - 18 VAC |
Low | 10.5 - 16 VAC |
Composite | 6 - 14 VAC |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
117244 | Connector |
C |
015-2580-01 | Switch Panel Harness |
D |
015-1465-01 | Lamp Socket Harness |
E |
015-2569-02 | Ground Wire |
F |
015-1324-04 | Connector |
G |
015-2421-01 | Flex / Fixed Arm Harness w/ LIN |
H |
015-3055-00 | Transformer / Suspension Tube Harness |
I |
015-0737-09 | Jumper Wire |
J |
015-0737-05 | Jumper Wire |
K |
015-0737-06 | Jumper Wire |
L |
015-0737-11 | Jumper Wire |
M |
015-3052-01 | Suspension Tube Harness - Use with 26.25" tube and longer |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
Track / Trolley: 153656 | Lighthead / Flex Arm: 153638 |
Serial Number | All | All |
Transformer Cold Resistance (Ohms) | |
---|---|
Primary | Secondary |
115 - 230 = 6.9 | S - S1 = .20 |
N - 115 = 3.0 | S1 - S2 = .08 |
N - 230 = 9.9 | S - S2 = .20 |
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
015-2569-00 | Ground Wire |
B |
015-2569-02 | Ground Wire |
C |
015-1465-01 | Lamp Socket Harness |
D |
117244 | Connector |
E |
015-2580-01 | Switch Panel Harness |
F |
015-1324-04 | Connector |
G |
015-1520-00 | Flex / Suspension Tube Harness |
H |
015-1512-00 | Track Suspension Tube Harness |
I |
015-1519-00 | Track Harness |
J |
015-0737-07 | Jumper Wire |
K |
015-0737-12 | Jumper Wire |
L |
015-0737-10 | Jumper Wire |
M |
015-0737-11 | Jumper Wire |
N |
015-1516-00 | Suspension Tube Harness - Use with 26.25" tube and longer |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
Track / Trolley: 153768 | Monitor / Flex Arm: 153770 | Lighthead / Flex Arm: 153638 | |
Serial Number | All NW, RE, PV Prefixes and V2200 thru V729364 | All NW, RE, PV Prefixes and V2200 thru V729364 | All NW, RE, PV Prefixes and V2200 thru V729364 |
Reference the Exorvision literature or website for information about the monitor.
Transformer Cold Resistance (Ohms) | |
---|---|
Primary | Secondary |
115 - 230 = 6.9 | S - S1 = .20 |
N - 115 = 3.0 | S1 - S2 = .08 |
N - 230 = 9.9 | S - S2 = .20 |
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
015-2171-00 | Power to Power Supply Harness |
B |
015-1170-04 | Ground Wire |
C |
015-2160-00 |
Light Power Harness |
D |
015-0737-07 | Jumper Wire |
E |
015-1519-00 | Track Harness |
F |
015-1512-00 | Suspension Tube Harness |
G |
015-1516-00 | Additional Suspension Tube Harness w/ 26.25" and longer |
H |
015-1520-00 | Flex / Suspension Tube Harness |
I |
015-1324-04 | Connector |
J |
015-2580-01 | Switch Panel Harness |
K |
117244 | Connector |
L |
015-2569-00 | Ground Wire |
M |
015-2569-02 | Ground Wire |
N |
015-1465-01 | Lamp Socket to PCB Harness |
O |
015-2197-00 |
Flex Arm Harness |
P |
015-2181-0x | 12 VDC, Audio, and VGA |
Q |
015-2180-00 |
Track Assembly Harness |
R |
015-2159-00 |
Video Cable |
S |
015-2158-00 |
Audio / Video Cable |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
Track / Trolley: 029-4856-0x |
Monitor / Flex Arm: 029-4739-00 |
Lighthead / Flex Arm: 029-4857-00 |
|
Serial Number | V761693 thru V946211 | V761693 thru V946211 | V761693 thru V946211 |
Order Kit 002-1393-00 to replace the Track Harness Assembly. Kit includes (1) Track Harness and (1) Flex Arm Harness.
Reference the Exorvision literature or website for information about the monitor.
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
015-2415-00 | Flex Arm Harness - see Note above |
B |
015-2499-00 | Track Harness - see Note above |
C |
015-2550-00 | Ground Wire |
D |
015-2171-00 | Power to Power Supply Harness |
E |
015-2495-00 | Light Power Harness |
F |
015-0737-07 | Jumper Wire |
G |
015-2496-00 | Light Track Harness |
H |
015-1512-00 | Track Suspension Tube Harness |
I |
015-1516-00 | Suspension Tube Harness - Use with 26.25" tube and longer |
J |
015-1520-00 | Flex / Suspension Tube Harness |
K |
015-1465-01 | Lamp Socket Harness |
L |
015-1324-04 | Connector |
M |
015-2569-02 | Ground Wire |
N |
117244 | Connector |
O |
015-2580-01 | Switch Panel Harness |
P |
015-2569-00 | Ground Wire |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
Track / Trolley: 029-4856-0x |
Monitor / Flex Arm: 029-4739-00 |
Lighthead / Flex Arm: 029-4857-00 |
|
Serial Number | V946212 Thru V1144326 | V946212 Thru V1144326 | V946212 Thru V1144326 |
Reference the Exorvision literature or website for information about the monitor.
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
002-1528-00 | Flex Arm Harness - includes adapter |
B |
015-2499-00 | Track Harness |
C |
015-2550-00 | Ground Wire |
D |
015-2171-00 | Power to Power Supply Harness |
E |
015-2495-00 | Light Power Harness |
F |
015-0737-07 | Jumper Wire |
G |
015-2496-00 | Light Track Harness |
H |
015-1512-00 | Track Suspension Tube Harness |
I |
015-1516-00 | Suspension Tube Harness - Use with 26.25" tube and longer |
J |
015-1520-00 | Flex / Suspension Tube Harness |
K |
015-1465-01 | Lamp Socket Harness |
L |
015-1324-04 | Connector |
M |
015-2569-02 | Ground Wire |
N |
117244 | Connector |
O |
015-2580-01 | Switch Panel Harness |
P |
015-2569-00 | Ground Wire |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
Track / Trolley: 029-4856-0x |
Monitor / Flex Arm: 029-4739-00 |
Lighthead / Flex Arm: 029-4857-00 |
|
Serial Number | V1144327 Thru V1878969 | V1144327 Thru V1878969 | V1144327 Thru V1878969 |
Reference the Exorvision literature or website for information about the monitor.
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
002-1528-00 | Flex Arm Harness - includes adapter |
B |
015-2499-00 | Track Harness |
C |
015-2550-00 | Ground Wire |
D |
015-2171-00 | Power to Power Supply Harness |
E |
015-2495-00 | Light Power Harness |
F |
015-0737-07 | Jumper Wire |
G |
015-2496-00 | Light Track Harness |
H |
015-1512-00 | Track Suspension Tube Harness |
I |
015-1516-00 | Suspension Tube Harness - Use with 26.25" tube and longer |
J |
015-1520-00 | Flex / Suspension Tube Harness |
K |
015-1465-01 | Lamp Socket Harness |
L |
015-1324-04 | Connector |
M |
015-2569-02 | Ground Wire |
N |
117244 | Connector |
O |
015-2580-01 | Switch Panel Harness |
P |
015-2569-00 | Ground Wire |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
Track / Trolley: 029-7244-xx | Monitor / Flex Arm: 029-4739-01 / 02 |
Lighthead / Flex Arm: 029-4857-00 |
153829-001 thru -008 |
153963-001 153963-002 thru -008 |
|||
Serial Number | V1878970 Thru V2493152 | V1878970 Thru V2493152 | V1878970 Thru V2493152 | V1878970 Thru V2493152 | V1878970 Thru V2493152 |
Reference the Exorvision literature or website for information about the monitor.
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
002-10088-00 | Flex Arm Harness - includes adapter |
B |
002-10089-00 | Track Harness |
C |
015-2550-00 | Ground Wire |
D |
015-3638-00 | Power to Power Supply Harness |
E |
015-10050-00 | Light Power Harness |
F |
015-0737-53 | Jumper Wire |
G |
015-2496-00 | Light Track Harness |
H |
015-1512-00 | Track Suspension Tube Harness |
I |
015-1516-00 | Suspension Tube Harness - Use with 26.25" tube and longer |
J |
015-1520-00 | Flex / Suspension Tube Harness |
K |
015-1465-01 | Lamp Socket Harness |
L |
015-1324-04 | Connector |
M |
015-2569-02 | Ground Wire |
N |
117244 | Connector |
O |
015-2580-01 | Switch Panel Harness |
P |
015-2569-00 | Ground Wire |
Q |
015-0947-47 | Ground Wire |
R |
015-0947-46 | Ground Wire |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
Track / Trolley: 029-7244-xx | Monitor / Flex Arm: 029-4739-01 / 02 |
Lighthead / Flex Arm: 029-4857-00 |
153829-001 thru -008 |
153963-001 153963-002 thru -008 |
|||
Serial Number | V2493153 Thru Present | V2493153 Thru Present | V2493153 Thru Present | V24931530 Thru Present | V2493153 Thru Present |
Reference the Exorvision literature or website for information about the monitor.
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
002-10088-00 | Flex Arm Harness - includes adapter |
B |
002-10089-00 | Track Harness |
C |
015-2550-00 | Ground Wire |
D |
015-3638-00 | Power to Power Supply Harness |
E |
015-10050-00 | Light Power Harness |
F |
015-0737-53 | Jumper Wire |
G |
015-2496-00 | Light Track Harness |
H |
015-1512-00 | Track Suspension Tube Harness |
I |
015-1516-00 | Suspension Tube Harness - Use with 26.25" tube and longer |
J |
015-1520-00 | Flex / Suspension Tube Harness |
K |
015-1465-01 | Lamp Socket Harness |
L |
015-1324-04 | Connector |
M |
015-2569-02 | Ground Wire |
N |
117244 | Connector |
O |
015-2580-01 | Switch Panel Harness |
P |
015-2569-00 | Ground Wire |
Q |
015-0947-47 | Ground Wire |
R |
015-0947-46 | Ground Wire |
S |
015-11613-00 | DC Barrel to 4 Pin Din Adapter |
T | 015-11612-00 | 4 Pin Din to DC Barrel Adapter |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
Wall Mount: 153640 | Cabinet Mount: 153641 | Lighthead / Flex Arm: 153638 | |||
Serial Number | All NW, RE, PV Prefixes and V2200 thru V1467258 | All NW, RE, PV Prefixes and V2200 thru V1467258 | All NW, RE, PV Prefixes and V2200 thru V1467258 |
Transformer Cold Resistance (Ohms) | |
---|---|
Primary | Secondary |
115 - 230 = 6.9 | S - S1 = .20 |
N - 115 = 3.0 | S1 - S2 = .08 |
N - 230 = 9.9 | S - S2 = .20 |
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
015-2569-02 | Ground Wire |
B |
015-2569-00 | Ground Wire |
C |
117244 | Connector |
D |
015-2580-01 | Switch Panel Harness |
E |
015-1465-01 | Lamp Socket Harness |
F |
015-1324-04 | Connector |
G |
015-1520-00 | Flex/Suspension Tube Harness |
H |
015-1523-00 | Wall Mount Tube Harness |
I |
015-1518-00 |
Transformer Harness |
J |
015-0737-07 | Jumper Wire |
K |
015-0737-08 | Jumper Wire |
L |
015-1510-04 | Power Cord |
M |
122618 | Plug |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
Wall Mount: 153640 | Cabinet Mount: 153641 | Lighthead / Flex Arm: 153939 | |||
Serial Number | V1467259 thru Present | V1467259 thru Present | V1467259 thru Present |
VAC at Board | |
---|---|
High | 14.5 - 19.5 VAC |
Medium | 13 - 18 VAC |
Low | 10.5 - 16 VAC |
Composite | 6 - 14 VAC |
Item | Part Number | Description |
---|---|---|
A |
015-2569-02 | Ground Wire |
B |
015-2569-00 | Ground Wire |
C |
117244 | Connector |
D |
015-2580-01 | Switch Panel Harness |
E |
015-1465-01 | Lamp Socket Harness |
F |
015-1324-01 | Connector |
G |
015-2421-00 | Flex / Arm Harness with LIN |
H |
015-3052-00 | Curved Arm Harness with LIN |
I |
015-3054-00 | Arm / Transformer Harness |
J |
015-0737-07 | Jumper Wire |
K |
015-0737-08 | Jumper Wire |
L |
015-1510-04 | Power Cord |
M |
122618 | Plug |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153639 | ||
Serial Number | All NW, RE, PV Prefixes and V2200 thru V1467258 |
Transformer Cold Resistance (Ohms) | |
---|---|
Primary | Secondary |
115 - 230 = 6.9 | S - S1 = .20 |
N - 115 = 3.0 | S1 - S2 = .08 |
N - 230 = 9.9 | S - S2 = .20 |
VAC at Bulb Settings | |
---|---|
High | 15.7 VAC |
Medium | 14.4 VAC |
Low | 12.8 VAC |
Composite | 9.8 VAC |
All voltages +/- 6%, taken across bulb. Add 0.3 VAC if taken at J2 on light PCB. |
Item | Part Number | Description |
---|---|---|
A |
015-2569-02 | Ground Wire |
B |
015-2569-00 | Ground Wire |
C |
117244 | Connector |
D |
015-2580-00 | Switch Panel Harness |
E |
015-1465-00 | Lamp Socket Harness |
F |
015-1324-04 | Connector |
G |
015-1521-00 | Flex Arm Harness |
H |
015-1517-00 | Universal Flex Arm Harness |
I |
015-0737-07 | Jumper Wire |
J |
015-0737-08 | Jumper Wire |
K |
015-1510-03 | Power Cord Assembly - Less plug |
L |
122618 | Plug |
Color Abbreviation Chart | ||
NSS = Not Sold Separately | AR = As Required | NLA = No Longer Available | CFN = Call for Number Always Specify Model and Serial Number |
Model |
153639 | ||
Serial Number | V1467259 thru Present |
VAC at Board | |
---|---|
High | 14.5 - 19.5 VAC |
Medium | 13 - 18 VAC |
Low | 10.5 - 16 VAC |
Composite | 6 - 14 VAC |
Item | Part Number | Description |
---|---|---|
A |
015-2569-02 | Ground Wire |
B |
015-2569-00 | Ground Wire |
C |
117244 | Connector |
D |
015-2580-00 | Switch Panel Harness |
E |
015-1465-00 | Lamp Socket Harness |
F |
015-1324-04 | Connector |
G |
015-1521-00 | Flex / Fixed Arm Harness |
H |
015-1517-00 | Fixed Arm / Transformer Harness |
I |
015-0737-07 | Jumper Wire |
J |
015-0737-08 | Jumper Wire |
K |
015-1510-03 | Power Cord Assembly - Less plug |
L |
122618 | Plug |
Color Abbreviation Chart | ||